Actuador Lineal Welact 4, W 4M, W 4P, W 4PM, W4EH, W4PFMH, W4PPLC
Compact actuator designed to move low and medium loads, has several versiones.Welact 4 for max 125 kg. and Welact 4P to max 400 kg, suitable for worki...
Actuator Welact 40, W 40F, W 40FM, W 40FMH, W 40FMHPLC
The models are W40 families have the highest performance regarding strength and speed, there are five speeds and five ranges of force. They have recir...
Linear Actuator Welact B10 RDE
Models that belong to the family Welact RDE B10 have the largest benefits in respect of forces and speeds, four and five speed range of forces. Have r...
The main difference between this actuator and the others is the possibility, linking with the control, of performing the piston feedback, viewing the ...
This actuator has the possibility, associating corresponding control, feedback of the position where the piston is via the use of a display provided b...
Linear Atuator Welact B10 and Welact B10H
Welact 10 family has the most quantity of variations respect the force and velocity. It has four velocities and five ranges of force. It has a robust ...
Welact 2, Welact 2P, W2H, W2PH, W2EH, W2PEH Linear Actuators
Compact actuator designed for moving light loads, suitable for working as much inner as outdoors. This joins many features of major price products....
Welact 200 and Welact 200P Linear Atuator
The main difference between this actuator and the others is the possibility, linking with the control, of performing the feedback, viewing the positio...
Welact 300, W 300P, W 300 PF y W 300 PF PLC Linear Atuator
This actuator has the possibility, linking with the control, of feedback on the position where the piston is. Available in 125kg for Welact 300 family...
Welact A10 family is designed for relatively light loads, it incorporates parts of more expensive families like Welact B10....
Compact for ligths and medium loads. Actuator available for working in small zones without sacrificing in power and reliability. Able to work so inn...
Compact actuator that works in little places without strength nor reliability sacrifice, suitable for working such as inner as outdoors....
WLR1 WLH1 and WLM1 Linear Atuator
These actuators have the advantage with respect to the WL1 version that can deliver a reading on the absolutely and relative WLR1 version reading the ...
First step
Determine Load Vs. Speed:
See each actuator section chart to find the best relationship between Load Vs Speed.
Second Step
Compare Life Vs. Duty cycle
Compare the actuator performance based in Life Vs.
Load and Duty Cycle Vs. Load charts.
Third Step
Select stroke length
To choose the desired length, check from the Quick Reference Guide or from the specific actuator pages.
Fourth Step
Verify design considerations:
Duty Cycle: Welact actuators are able to run at 25% rated at maximum load. Duty cycle is the time the actuator works vs. cooling time.For example 25% Duty cycle in one minute cycle means, that the actuator runs 15 seconds and then must be stopped for 45 seconds.
Side loading and shock loading restrictions:Our actuators may support light shock loading. It is recommended to decrease or remove this kind of loads.Side loading, loads are not axial with actuator axis, may dramatically reduce life.
Cantilever mounting should be eliminated to avoid rod bending.Kind of mounting: We have one kind of mounting with two parallel pins.
Fifth Step
Control Selection:
See the Control System Section or in the actuator specific pages for choosing each actuator control.
For best actuator performance, to avoid premature fault, rod bending, etc it is recommended to install the support with U shape, NEVER with cantilever mounting.