– Input: 12 to 24 VDC.
– Length of work: 50.8-101.6-203.2-304.80-457.20 and 609.6 mm
– Load Capacities: 100-125- 250-500 and 650 kg.
– Percentage of working time: 25% at full load.
– Motor Protection: Without motor protection (control boxes have our protection as standard).
– Cable shield. Thermal to 12vdc (Standard, Fast and extra fast): Polyswitch 15 amp.
– Cable shield. Thermal for 12vcc- (slow): Polyswitch 4amp.
– Cable shield. Thermal for 24vcc- (Standard, Fast and extra fast): Polyswitch 7 amp.
– Cable shield. Thermal for 24vcc- (Slow): Polyswitch 2 amp.
– Limits career: No, Optional sensors on the outside of the machine.
– Thread: balls.- Temperature range: -26 to 65 ªC.
– Exterior Casing: Aluminum.
– Environmental Protection: IRAM 2444/82. IP 65.
– Test implemented: Protection of 96 hours of salt spray.
– Section and Diameter Cables: 2.6 mm2 or 1.8 mm (see figure for this purpose).
– Limit switch: Yes Internal, External -model M.
– Connectors: Optional. (See section for this purpose)
– Mounting: U-shaped or similar.
– Torque Start / Stop: No
– Static load: 1500 kg. For all models.
– Life: According models.
– Measurement of packing box: Length: 575mm; Width: 160mm; Height: 90mm